100% Genuine
Lowest price
Free shipping

UPS Norden 100kVA / 100kW Double Conversion Tower Type 3/3 with 5inch LCD display (External Battery) CN933100U-5L

5 products sold in last 18 hours
Selling fast! Over 8 people have in their cart
  • Power Capacity: 100,000 VA / 100,000 W
  • Output Waveform: Pure sine wave
  • Internal Battery: 30–50 x 12V/9Ah (±180V ~ ±300VDC)
  • External Battery Support: No
  • Display: LCD showing load, battery, voltage, frequency, operation mode, bypass, and fault status
  • Protections: EMI filter, surge protection, overload, overtemperature, short circuit, low battery, fan failure, EPO
  • Connectivity: USB, RS232, RS485, parallel port, dry contact (optional SNMP, relay card)
  • Weight: 147 kg
27 people are viewing this right now
  • Check Mark Estimated Delivery : Up to 4 business days
  • Check Mark Free Shipping & Returns : On all orders over $200
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
  • Apple Pay
Guaranteed Safe And Secure Checkout

UPS Norden 100kVA / 100kW Double Conversion Tower Type 3/3 UPS with 5inch LCD display is an online double-conversion UPS with three-phase input and output, featuring an output power factor of 1. Its tower-type design allows for parallel operation of up to 6 units, making it ideal for industrial and critical business applications that require strict voltage regulation.

General Features

  • Wide Input Voltage Range: Compatible with unstable power environments thanks to its wide 140–485Vac range (phase: 80–280Vac).

  • High Input Power Factor (up to 0.99): Reduces electrical losses and improves energy efficiency.

  • Superior High Efficiency: With a three-level inverter, the UPS achieves up to 96% efficiency, optimizing operational performance.

  • Output Power Factor 1.0: Delivers 100% real power, ensuring efficient operation with all load types, including unbalanced loads.

  • Supports up to 6 Units in Parallel: Enables capacity expansion or N+X redundancy setup, increasing flexibility and system reliability.

  • Low Input Current Harmonic (<3% THDi): Reduces grid pollution and protects the shared power system.

  • High Charging Current, Flexible Battery Configuration: Supports 30–50 battery cells, adaptable to various backup requirements.

  • High Load Compatibility: Operates reliably with inductive, capacitive, and unbalanced loads.

  • Power Walk-in Function: Limits inrush current during startup, protecting generators and extending equipment lifespan.

  • LBS (Load Bus Synchronization): Allows two independent UPS systems to synchronize, enhancing power continuity and safety.

  • Versatile Communication: Supports USB, RS232, RS485, with optional expansions like SNMP and dry contact card for remote monitoring.

Power Capacity
VA 100,000
Watts 100,000
Input
Input Voltage 380/400/415Vac (3Ph+N+PE)
Input Voltage Range 138~305Vac for 40% Load; 305~485Vac for Full Load
Operating Frequency Range 40~70Hz
Input Power Factor ≥0.99
Maximum Voltage 220Vac:+25% (options: +10%, +15%, +20%)
230V: +20% (options: +10%, +15%)
240V: +15% (option: +10%)
Minimum Voltage -45% (options: -20%, -30%)
Bypass Frequency Range ±10%
Generator Compatibility Supported
Input THDi <3% (linear load)
Output
Output Voltage 380/400/415Vac (3Ph+N+PE)
Output Power Factor 0.9
Voltage Regulation ±1%
Frequency Range (Line Mode) ±1% / ±2% / ±4% / ±5% / ±10% of nominal frequency (Selectable)
Frequency Range (Battery Mode) 50/60Hz (±0.2%)
Crest Factor 3:01
Output THDv ≤2% (linear load), ≤4% (non-linear load)
Battery
Battery Voltage ±180 to ±300Vdc (30–50 batteries of 12V each)
Charging Current 40A
System Features
Transfer Time 0ms (mains to battery / mains to bypass)
Overload (Line Mode) ≤110%: 60 minutes
≤150%: 1 minute
>150%: bypass in 1.2 seconds
Overload (Bypass Mode) 30°C: 135% long-term
40°C: 125% long-term
>1000%: 100ms
Alarms Overload, utility fault, UPS fault, low battery, etc.
Protections Short circuit, overload, overtemperature, low battery, fan failure
Communication Interfaces USB, RS232, RS485, Parallel port, Dry contact, Smart slot, LBS, SNMP card (optional), Relay card (optional)
Environmental
Operating Temperature 0~40°C
Storage Temperature -25~55°C
Humidity Range 0~95% RH (Non-condensing)
Altitude <1500m
Noise Level <62dB
Standards
Safety IEC/EN62040-1, IEC/EN62477-1
EMC IEC/EN62040-2 (IEC61000-2-2, 4-2 ~ 4-11)
Physical
Dimensions (WxDxH) 442 × 850 × 1200 mm
Net Weight(kg) 147

Reviews

There are no reviews yet.

Be the first to review “UPS Norden 100kVA / 100kW Double Conversion Tower Type 3/3 with 5inch LCD display (External Battery) CN933100U-5L”

Your email address will not be published. Required fields are marked *