UPS Norden 15kVA / 15kW Double Conversion Rack/Tower 3/3, 3/1 with TFT Display (External Battery) CN5315MP-RM
Power Capacity: 15,000 VA / 15,000 W
Output Waveform: Pure Sine Wave
Battery: 30–50 units of 12V batteries (with neutral wire)
Charging Current: Up to 18A (adjustable according to battery capacity)
Display: LCD showing voltage, frequency, load, operating mode, fault, battery status
Protection: Overload, short circuit, overtemperature, low battery, system fault
Alarm: Audible + fault display
Communication Interfaces: RS232, RS485, USB, dry contact, SNMP slot/relay card (optional), BMS, EPO
Transfer Time: 0ms (to battery or bypass)
Noise Level: <55 dB
Dimensions (W x D x H): 443 x 580 x 131 mm
Weight: 31 kg
- Estimated Delivery : Up to 4 business days
- Free Shipping & Returns : On all orders over $200
UPS Norden 15kVA / 15kW Double Conversion Rack/Tower 3/3, 3/1 with TFT Display is an online double conversion UPS supporting 3/3 and 3/1 configurations, with an output power factor of 1. The device features a flexible design allowing conversion between rack and tower formats, and supports parallel redundancy, making it highly suitable for data center applications and critical infrastructure systems.
Key Features
-
Flexible Rack/Tower design with smart LCD display
-
N+X parallel redundancy support: Connect up to 4 units to increase reliability
-
True online double conversion, fully digitally controlled
-
Wide input frequency range: 40~70Hz
-
Wide input voltage range: 208~478Vac
-
Low input current distortion: THDi < 3%
-
Maximum charging current up to 20A (adjustable)
-
Dual input support
-
ECO mode: High energy-saving efficiency
-
Flexible configuration support: 3/3, 3/1, and 1/1
-
Generator compatible
-
Cold Start function: Enables startup without utility power
-
Self-test on startup: Ensures stable operation from the beginning
-
Frequency conversion mode: 50Hz/60Hz
-
Smart fan speed control: Reduces noise and extends lifespan
-
Configurable battery quantity: 30–50 batteries optional
Capacity | kVA | 15kVA | |
Watts | 15000 | ||
Input | Normal Voltage | 380/400/415Vac (3Ph+N+PE) 220/230/240Vac (L+N+PE) | |
Operating Voltage Range | 208~478Vac | ||
Operating Frequency Range | 40~70Hz (50/60Hz Auto-Sensing) | ||
Power Factor | ≥0.99 | ||
Bypass voltage range | Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 240V:+15% (Optional+10%) Min.voltage:-45% (Optional-20%,-30%), 230V:+20% (Optional+10%,+15%) | ||
ECO range | Same as the bypass | ||
Generator input | Support | ||
Output | Rated voltage | 380/400/415Vac (3Ph+N+PE) 220/230/240Vac (L+N+PE) | |
Power factor | 1 | ||
Voltage Regulation | ±1% | ||
Frequency | Line mode | ±1%/±2%/±4%/±5%/±10% of the rated frequency (Optional) | |
Bat. mode | 50/60(±0.1)Hz | ||
Crest Factor | 3:01 | ||
Harmonic Distortion (THDv) | ≤2% with linear load, ≤5% with non-linear load | ||
Efficiency | 94.50% | ||
Output Waveform | Pure Sine Wave | ||
Battery | Battery Numbers | 30/32/34/36/38/40/42/44/46/48/50pcs with Neutral | |
Charging current | 18A Max.(charge current can be set according to battery capacity installed) | ||
System | Transfer time | Mains to battery:0ms; Inverter to bypass:0ms | |
Features | Overload | Line mode | Load≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, ≥150% turn to bypass mode immediately |
Bypass mode | Breaker ( Load < 125%, long-term operation) | ||
Short circuit | Hold whole system | ||
Overheat | Line mode: Turn to bypass; Backup mode: shut down UPS immediately | ||
Battery low | Alarm and switch off | ||
Self-diagnostics | Upon power on and software control | ||
Battery | Advanced battery management | ||
Audible & Visual alarms | Line failure, Battery under voltage, Overload, System fault | ||
LED & LCD display | Line mode, Bat. mode, Eco mode, Bypass mode, Battery under voltage, Overload & UPS Fault | ||
LCD display | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time | ||
Communication interface | RS232, RS485, Parallel, Intelligent Slot(SNMP card/ Relaycard (Optional)),BMS (Optional),EPO port Output port, MAINTAIN-AUXSWS port | ||
Environment | Operating temperature | 0~40°C | |
Storage temperature | -25~55°C | ||
Humidity range | 0~95% (Non-condensing) | ||
Altitude | <1500m | ||
Noise level | <55dB | ||
IP Rating | IP 20 | ||
Standards | Safety | CE; IEC/EN62040-1,IEC/EN62477-1 | |
EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 | ||
Physical | Dimension WxDxH(mm) | 443 x 580 x 131 | |
Net Weight (kg) | 31 |
Show reviews in all languages (1)
Reviews
There are no reviews yet.