100% Genuine
Lowest price
Free shipping

UPS Norden 150kVA / 150kW Double Conversion Tower Type 3/3 with 5inch LCD display (External Battery) CN933150U-5L

16 products sold in last 11 hours
Selling fast! Over 18 people have in their cart
  • Power Capacity: 150,000 VA / 150,000 W

  • Waveform: Pure sine wave

  • Battery: 30–50 x 12V (±180V ~ ±300VDC)

  • Charging Current: 60A

  • Display: LCD – voltage, load, frequency, mode, fault, battery

  • Protection: Overload, short circuit, overtemperature, fan/UPS/power failure, low battery

  • Alarm: Audible + LCD display

  • Communication Interfaces: USB, RS232, RS485, dry contact, SNMP slot / relay card

  • Transfer Time: 0ms (to battery / bypass)

  • Noise Level: <60 dB

  • Dimensions: 442 × 850 × 1200 mm

  • Weight: 190 kg

27 people are viewing this right now
  • Check Mark Estimated Delivery : Up to 4 business days
  • Check Mark Free Shipping & Returns : On all orders over $200
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
  • Apple Pay
Guaranteed Safe And Secure Checkout

UPS Norden 150kVA / 150kW Double Conversion Tower is an online double conversion UPS system with three-phase input and output, featuring a power factor of 1. Its tower-type design supports parallel operation of up to six units, making it ideal for industrial and critical business applications with strict voltage regulations.

General Features

  • Wide Input Voltage Range: Compatible with unstable power environments thanks to a wide range of 140–485Vac (phase: 80–280Vac).

  • High Input Power Factor (up to 0.99): Reduces power loss and improves energy efficiency.

  • Superior High Efficiency: With a three-level inverter, the system achieves up to 96% efficiency, optimizing operational performance.

  • Output Power Factor 1.0: Delivers 100% real power, effectively supporting all types of loads, including unbalanced loads.

  • Supports up to 6 Units in Parallel: Enables capacity expansion or N+X redundancy configuration, enhancing flexibility and reliability.

  • Low Input Current Harmonic Distortion (<3% THDi): Minimizes interference to the power grid, protecting the common power system.

  • High Charging Current and Flexible Battery Configuration: Supports battery groups of 30–50 cells, meeting various backup power requirements.

  • High Load Compatibility: Operates stably with inductive, capacitive, and unbalanced loads.

  • Power Walk-in Function: Limits inrush current during startup, protecting generators and extending equipment lifespan.

  • LBS (Load Bus Synchronization) Function: Allows two independent UPS systems to synchronize, enhancing power continuity and safety.

  • Versatile Communication: Supports USB, RS232, RS485, with optional expansions like SNMP and dry contact cards for remote monitoring.

Power Capacity
VA 150 000
Watts 150 000
Input
Input Voltage 380/400/415Vac (3Ph+N+PE)
Input Voltage Range 305~485Vac (full load)
138~305Vac (load 40%)
Operating Frequency Range 40~70Hz
Input Power Factor ≥0.99
Maximum Voltage 220Vac:+25% (options: +10%,+15%,+20%)
230V: +20% (options: +10%,+15%)
240V: +15% (option: +10%)
Minimum Voltage -45% (options: -20%,-30%)
Bypass Frequency Range ±10%
Generator Compatibility Supported
Input THDi <3% (linear load)
Output
Output Voltage 380/400/415Vac (3Ph+N+PE)
Output Power Factor 0.9
Voltage Regulation ±1%
Frequency Range (Line Mode) ±1%/±2%/±4%/±5%/±10% of nominal frequency (Selectable)
Frequency Range (Battery Mode) 50/60(±0,2%)Hz
Crest Factor 3:1
Output THDv ≤2% (linear load), ≤4% (non-linear load)
Battery
Battery Voltage ±180/±192/±204/±216/±228/±240/±252/±264/±276/±288/±300Vdc (30/32/34/36/38/40/42/44/46/48/50 pcs)
Charging Current 60A
System Features
Tranfer time 0ms (mains to battery / mains to bypass)
Overload (Line Mode) ≤110%: 60 minutes
≤150%: 1 minute
>150%: transfer to bypass in 1.2 seconds
Overload (Bypass Mode) 30°C: 135% long-term
40°C: 125% long-term
>1000%: 100ms
Alarms Overload, utility fault, UPS fault, low battery, etc.
Protections Short circuit, overload, overtemperature, low battery, fan failure
Communication Interfaces USB, RS232, RS485, Parallel port, Dry contact, Smart slot, LBS, SNMP card (optional), Relay card (optional)
Environmental
Operating temperature 0~40°C
Storage temperature -25~55°C
Humidity range 0~95% (Non-condensing)
Altitude <1500m
Noise level <60db
Standards
Safety IEC/EN62040-1, IEC/EN62477-1
EMC IEC/EN 62040-2 (IEC 61000-2-2, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC61000-4-11)
Physical
Dimension WxDxH(mm) 442x850x1200
Net Weight (kg) 190

Reviews

There are no reviews yet.

Be the first to review “UPS Norden 150kVA / 150kW Double Conversion Tower Type 3/3 with 5inch LCD display (External Battery) CN933150U-5L”

Your email address will not be published. Required fields are marked *