  • Capacity: 2000 VA / 1800 Watts

  • Transfer Time: AC to DC – 0 ms, Inverter to Bypass – 4 ms

  • Waveform: Pure Sine Wave

  • Battery: 12V / 9Ah

  • Display: LCD showing load level, battery status, operating mode, and faults

  • Protection: Short circuit, overload, overvoltage

  • Alarm: Audible alerts for battery, load, and faults

  • Communication Ports: USB or RS232, optional SNMP

  • Dimensions: 440 × 660 × 86.5 mm

30 people are viewing this right now
  • Check Mark Estimated Delivery : Up to 4 business days
  • Check Mark Free Shipping & Returns : On all orders over $200
  • Visa Card
  • MasterCard
  • American Express
  • Discover Card
  • PayPal
  • Apple Pay
Guaranteed Safe And Secure Checkout

UPS Norden 2kVA / 1800W Online Transformerless (Internal Battery) is an optimal solution for delivering continuous and stable power protection, ideal for critical electronic equipment such as computers, servers, and network systems. Featuring a transformerless design, this UPS reduces overall weight and size while improving energy efficiency and performance.

The Online Transformerless UPS is the ideal choice for businesses and organizations requiring a reliable, uninterrupted power solution that maintains operational stability and protects vital equipment from power-related risks.


Key Features of the Online Transformerless UPS

  • High Power Density: Maximizes space efficiency while optimizing performance.

  • True Online Double Conversion with Full Digital Control: Ensures continuous and stable power supply with comprehensive digital management.

  • Selectable Output Voltage (220/230/240Vac): Users can customize the output voltage to match specific equipment requirements.

  • Wide Input Voltage Range (110~300Vac): Operates effectively across a broad range of input voltages.

  • High Input Power Factor (0.99) with PFC: Enhances energy efficiency and reduces power waste.

  • Maximum Charging Current up to 12A (for long backup models): Supports fast and efficient battery charging for extended runtime.

  • Emergency Power Off (EPO): Integrated emergency shutdown feature ensures safety in critical situations.

  • ECO Mode for Energy Saving: Automatically reduces power consumption during low load conditions.

  • Versatile Communication Interfaces: RS232 (optional USB, dry contact, SNMP card) for flexible monitoring and management.

  • Startup Self-Test: Automatically performs system diagnostics on startup to ensure full operational readiness.

  • Generator Compatibility: Operates seamlessly with generator input, ensuring continuous power in all scenarios.

  • Cold Start Function: Allows UPS startup without an AC power source.

  • Intelligent Fan Speed Control: Automatically adjusts fan speed based on temperature, reducing noise and extending system lifespan.

  • Optional Universal Outlets: Supports a wide range of plug types for versatile equipment compatibility.

Capacity VA 2000
Watts 1800
Phase Single phase with ground
Input Normal Voltage 208/220/230/240Vac
Operating Voltage Range 110~300Vac
Frequency Range 45~55Hz/55~65Hz (Auto-detect)
Power Factor ≥0.99 @Nominal voltage(100% load)
Output Output Voltage 208/220/230/240Vac
Power Factor 0.9
Voltage Regulation ±1%
Frequency Line mode 46~54Hz / 56~64Hz
(Synchronized range)
Bat. mode 50Hz / 60Hz ±0.1H
Crest Factor 3:01
Harmonic Distortion (THDv) ≤3% THD(Linear load)
≤5% THD(Non-linear load)
Transfer time AC to DC Zero
Inverter to bypass 4ms(Typical)
Waveform Pure sinewave
Efficiency AC Mode 90%
Battery Mode 87%
Battery Internal Battery Type 12V/9AH
Numbers 6
Typical Recharging Time 4 hours recover to 90% capacity
Charging current(max.) 1A
Charging Voltage 82.1Vdc ±1%
Battery External Battery Numbers 6
Charging Voltage 82.1Vdc ±1%
Charging Current 2A
Indicators LCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
Alarm Battery Mode Beeping every 4 seconds
Battery Low Beeping every second
Overload Beeping twice every second
Fault Continuously beeping
Physical Dimension W x D x H (mm) Standard model 440x460x86.5/440x600x86.5
Long run model 440x600x86.5
Weight  (kg) Standard model 19.5/25
Long run model 10.5
Environment Humidity 20-90% RH @ 0-40°C (Non-condensing)
Noise level <50dB @ 1 Meter
Management Smart RS232/USB Supports Windows® 7/8/10, Linux, FreeBSD and MAC
Optional SNMP Power management from SNMP manager and web browser
Standards Safety IEC/EN62040-1,IEC/EN62477-1
EMC IEN/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8,IEC61000-4-11,IEC61000-2-2